Getting Started

Adjusting the Transmissive Media Sensor Assembly

Position

When the XiII printer is powered on, it performs a self test and configures its operating characteristics. Some of these characteristics are determined by the position of the Transmissive Media Sensor. See Figure 4 on page 16. The factory-set position is sufficient for most types of media. However, if media sensor adjustments are needed, follow the procedures below.

Note: The Reflective (Black-Mark) Media Sensor position is not adjustable; it is positioned to accommodate all black-mark media that meets the specifications listed in “Media Specifications” on page 86.

Note: If you are using continuous media (no gap, notch, or hole between labels) or black-mark media, position the transmissive sensor over the media so that the printer can detect an out-of-paper condition. The factory-set position should be sufficient for this purpose.

The Transmissive Media Sensor Assembly consists of two sections. The media passes between a light source and a light sensor. The light source is positioned below the media, while the light sensor is positioned above the media.

This adjustment aligns the position of the light sensor with the notch or edge of the label.

Zebra XiII Printer User’s Guide

15