Technical Specications
E-XP2i Models
U.S. Metric
Maximum Fluid Working Pressure
Pressure 3500 psi 24.1 MPa, 241 bar
Maximum Fluid Temperature
E-XP2i 180°F 82°C
Maximum Output
Output 2 gpm 7.6 lpm
Maximum Heated Hose Length
Length 310 ft 94 m
Output per Cycle
A and B 0.0203gal. 0.0771 liter
Operating Ambient Temperature Range
Temperature 20° to 120°F -7° to 49°C
Auxiliary Power Available
Voltage 120 Vac or 240 Vac, 60 Hz
Engine
Model Perkins 404–22G, 2.2 L, 29 HP
Alternator
Model MeccAlte22kW,240V,1PH,60Hz,pancakestyle
Battery Requirements
Voltage 12 Vdc
Minimum Cold Cranking Amps 800CCA
Connection Type Post Style
Recommended Battery Size
BC Group Number 34
Length 10.25 in. 260 mm
Width 6.81 in. 173 mm
Height 7.88 in. 200 mm
Booster Heater Power
Wattage 4000 Watts
104 3A1705J