Troubleshooting

 

 

 

 

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Location

 

 

 

 

DADX

MCM

ALARM

Pump Runaway

Flow rate is too large

Mix chamber too large for

 

 

 

 

 

system selected. Use mix

 

 

 

 

 

chamber rated for system.

 

 

 

 

 

Ensure the system has

 

 

 

 

 

chemical and the feed

 

 

 

 

 

pumps are operating

 

 

 

 

 

correctly.

 

 

 

 

 

No material in pumps.

 

 

 

 

 

Verify pumps are

 

 

 

 

 

supplying chemical. If

 

 

 

 

 

necessary, replace or refill

 

 

 

 

 

drums.

 

 

 

 

 

Inlet ball valves are closed.

 

 

 

 

 

Open ball valves.

DE0X

MCM

ALARM

Pump Cycle

Faulty or missing cycle

Check wiring between

 

 

 

Switch Fault

switch.

cycle switch and MCM

 

 

 

 

 

port 6.

F9DX

MCM

ALARM

Pressure Flow

Mix chamber is too

Reference the pressure

 

 

 

Cutback

large for the set

flow curves and select a

 

 

 

 

pressure.

tip size that is the correct

 

 

 

 

 

size for the set pressure.

 

 

 

 

 

See Performance Charts,

 

 

 

 

 

page 99.

H1MH

Hose

ALARM

Low Line

Line frequency is below

Check frequency. If

 

 

 

Frequency

55 Hz.

out of tolerance, see

 

 

 

 

 

supplied 120/240V

 

 

 

 

 

alternator manual for

 

 

 

 

 

repair instructions.

H4MH

Hose

ALARM

High Line

Line frequency is above

Check frequency. If

 

 

 

Frequency

65 Hz.

out of tolerance, see

 

 

 

 

 

supplied 120/240V

 

 

 

 

 

alternator manual for

 

 

 

 

 

repair instructions.

K8NM

MCM

ALARM

Locked Rotor

Locked rotor.

Replace motor. See

 

 

 

 

 

system repair manual.

 

 

 

 

Chemical pump is

Repair or replace pump.

 

 

 

 

stuck.

See system repair manual.

L1AX

ADM

ALARM

Low Chemical

Tanks low on material.

Fill tanks with material.

 

 

 

Level A

 

 

L1BX

 

 

Low Chemical

 

 

 

 

 

Level B

 

 

78