Troubleshooting

 

 

 

 

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Position

 

 

 

 

T2DA

Boost A

ALARM

Low Chemical

Flow is too high at current

Use a smaller mix chamber

T2DB

Boost B

 

Temperature

setpoint.

that is rated for the unit in

 

 

 

use.

 

 

 

 

 

 

 

 

 

Bad heater(s)

Confirm resistance of heater

 

 

 

 

 

is 23–26.5 ohms. Replace if

 

 

 

 

 

OL/open loop.

T2DH

Hose

ALARM

Low Chemical

Cold chemical in

Recirculate heated chemical

 

 

 

Temperature

unheated portion of

back to drum in cold

 

 

 

 

system passed hose FTS

conditions before startup.

 

 

 

 

at startup.

 

T2DE

Heat

ADVISORY

Low Temperature

Radiator fan will not stop.

Replace fan relay. See

 

Exchanger

 

Coolant Outlet

 

system repair manual.

 

 

 

 

Engine thermostat is

Replace thermostat. See

 

 

 

 

stuck open.

Perkins distributor to

 

 

 

 

 

replace.

T3NM

MCM

ADVISORY

High Motor

Motor is operating

Run the system at a

 

 

 

Temperature

outside of pressure

lower duty cycle or with a

 

 

 

 

flow curve. The system

smaller mix chamber. See

 

 

 

 

is running at a lower

Performance Charts, page

 

 

 

 

setpoint to preserve

99.

 

 

 

 

motor life.

 

T4AE

Heat

ALARM

High Chemical

Manual valve switch (MV)

Open cabinet cover and turn

T4BE

Exchanger

 

Temperature Hx A

on load center board is in

switch to the OFF position.

 

 

(T4AE)

the ON position.

 

 

 

 

 

 

 

 

High Chemical

A or B side control valve

Disconnect connector

 

 

 

solenoid is stuck in the

from valve solenoid coil.

 

 

 

Temperature Hx B

 

 

 

(T4BE)

open position. Debris

If temperature does not

 

 

 

in valve diaphragm

decrease, rebuild solenoid.

 

 

 

 

 

 

 

 

or plunger preventing

 

 

 

 

 

spring-loaded closed

 

 

 

 

 

function.

 

 

 

 

 

Short on load center

See Load Center

 

 

 

 

board. If the blue and red

Diagnostics in the system

 

 

 

 

LEDs are on while the

repair manual.

 

 

 

 

heat is off, then the load

 

 

 

 

 

center board is bad.

 

 

 

 

 

(T4BE only) J6 connector

Reconnect J6 connector

 

 

 

 

on load center “Heat

on load center in centered

 

 

 

 

Valves” location is not

location.

 

 

 

 

centered.

 

 

 

 

 

A and B heat

See System Repair Manual

 

 

 

 

exchanger RTD cables

for correct connection.

 

 

 

 

cross-connected to

 

 

 

 

 

splitter cable.

 

82

3A1705J

Page 82
Image 82