Electrical Connections
Connect air compressor, breathing air, and auxiliary power electrical connections to the specified circuit breakers. See Circuit Breakers, page 28.
1.Remove one or more
Connect Feed Pumps
1.Install feed pumps (K) in component A and B supply drums. See
Typical Installation, with circulation, page 13 and Typical Installation, without circulation, page 14.
2.Seal component A drum and use desiccant dryer
(M)in vent.
3.Install agitator (L) in component B drum, if necessary.
4.Connect supply hoses from feed pumps to the component A and component B material inlets on the system. Ensure A and B inlet valves are closed.
Note
Supply hoses from feed pumps should be 3/4 in. (199 mm) ID.
5.Connect air lines to proportioner. Ensure components are properly connected to correct location.
Setup
PG PF
PH | PJ |
Ref | Air Outlet |
PF | A Pump |
PG | B Pump |
PH | Agitator |
PJ | Gun |
Note
Agitator air supply (PH) includes a small internal restriction orifice to limit the air flow to minimize air compressor load. Maximum supplied air flow is 2.0 scfm (0.1 m3/min) at 100 psi (0.7 MPa, 7 bar). Designed for use with Twistork agitator 224854. Do not use the agitator air outlet (PH) for any other component.
Breathing Air
Breathing the air from the compressed air supply can cause serious injury if inhaled.
•Only use an independent and approved breathing air system with adequate air flow to provide clean breathable air.