Graco 3A1705J Home System Off, Home System Active, Home System With Error, Targets

Models: 3A1705J

1 106
Download 106 pages 9.62 Kb
Page 50
Image 50

Advanced Display Module (ADM) Operation

Home — System Off

This is the home screen when the system is off. This screen displays actual temperatures, actual pressures at the fluid manifold, jog speed, coolant temperature, and number of cycles.

Home — System Active

When the system is active, the home screen displays actual temperature for heat zones, actual pressures at the fluid manifold, coolant temperature, jog speed, the number of cycles, along with all associated control soft keys.

Use this screen to turn on heat zones, view coolant temperature, start the proportioner, stop the proportioner, park the component A pump, enter jog mode, and clear cycles.

Home — System With Error

Active errors are shown in the status bar. The error code, alarm bell, and description of the error will scroll in the status bar.

1.Press to acknowledge the error.

2.See for corrective action.

Targets

Use this screen to define the setpoints for the A Component Temperature, B Component Temperature, heated hose temperature, and pressure.

Maximum A and B temperature for systems without booster heat: 140°F (60°C)

Maximum A and B temperature for systems with booster heat: 180°F (82°C)

Maximum heated hose temperature: 10°F (5°C) above the highest A or B temperature setpoint or 180°F (82°C).

Note

If the remote display module kit is used, these setpoints can be modified at the gun.

50

3A1705J

Page 50
Image 50
Graco 3A1705J important safety instructions Home System Off, Home System Active, Home System With Error, Targets