Graco 3A1705J MBN0 MCM Advi, Sory, Mmux USB Advi, P4AX MCM Alarm, P4BX, P6AX MCM Alarm, P6BX

Models: 3A1705J

1 106
Download 106 pages 9.62 Kb
Page 79
Image 79

 

 

 

 

 

Troubleshooting

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Location

 

 

 

 

MBN0

MCM

ADVI-

Motor Brush

Brushes have worn

Replace Brushes. See

 

 

SORY

Wear

down and need

system repair manual.

 

 

 

 

replacing.

 

MMUX

USB

ADVI-

USB Log Full

USB logs have reached

Use a USB drive and

 

 

SORY

 

a level were data loss

download all logs.

 

 

 

 

will occur if logs are not

 

 

 

 

 

downloaded.

 

P4AX

MCM

ALARM

Over Pressure A

System pressurized

Turn on the heat and allow

P4BX

 

 

Over Pressure B

before allowing heat to

the hose to reach the

 

 

reach setpoint.

setpoint before turning on

 

 

 

 

 

the pumps.

 

 

 

 

Bad pressure

Verify the ADM pressure

 

 

 

 

transducer.

reading the analog gauges

 

 

 

 

 

at the manifold. Replace

 

 

 

 

 

transducers if they do not

 

 

 

 

 

match. See system repair

 

 

 

 

 

manual.

 

 

 

 

E-XP2i system

Ensure rotary switch on

 

 

 

 

configured as E-30i.

MCM is set to position 0

 

 

 

 

 

for E-30i.

P6AX

MCM

ALARM

Pressure

Loose/bad connection.

Check to ensure the

P6BX

 

 

Transducer

 

pressure transducer is

 

 

Fault A

 

properly installed and

 

 

 

 

 

 

 

Pressure

 

all wires are properly

 

 

 

 

connected.

 

 

 

Transducer

 

 

 

 

Bad sensor.

Check if the error

 

 

 

Fault B

 

 

 

 

follows the transducer.

 

 

 

 

 

 

 

 

 

 

Disconnect transducer

 

 

 

 

 

cable from #8 and #9

 

 

 

 

 

connectors on MCM.

 

 

 

 

 

Reverse A and B

 

 

 

 

 

connections and check

 

 

 

 

 

if the error follows. If

 

 

 

 

 

the error follows the

 

 

 

 

 

transducer, replace the

 

 

 

 

 

pressure transducer. See

 

 

 

 

 

system repair manual. If

 

 

 

 

 

the error does not follow,

 

 

 

 

 

replace MCM. See system

 

 

 

 

 

repair manual.

3A1705J