Graco 3A1705J important safety instructions Startup

Models: 3A1705J

1 106
Download 106 pages 9.62 Kb
Page 55
Image 55

Startup

Startup

To prevent serious injury, only operate Reactor with all covers and shrouds in place.

NOTICE

Proper system setup, startup, and shutdown procedures are critical to electrical equipment reliability. The following procedures ensure steady voltage. Failure to follow these procedures will cause voltage fluctuations that can damage electrical equipment and void the warranty.

1.Check generator fuel level.

Running out of fuel will cause voltage fluctuations that can damage electrical equipment.

2.Check coolant levels.

Inspect the level of coolant inside the engine coolant expansion bottle (EB) and heat exchanger coolant expansion bottle (HB).

6.Start the generator.

Press start button twice on the engine control module. The controller will automatically sequence glow plug warming and crank operations. Allow engine to reach full operating speed.

Note

Engine will not start if main power switch is in the on position.

Note

If the engine control module screen does not light up after the start button is pressed, see the system repair manual.

7.Turn main power switch ON.

HOT

HOT

 

COLD

3.Check fluid inlet screens.

Before daily startup, ensure that the fluid inlet screens are clean. See Flush Inlet Strainer Screen, page 67

4.Check ISO lubrication reservoir.

Check level and condition of ISO lube daily. See Pump Lubrication System, page 68.

5.Confirm main power switch is OFF before starting generator.

When the system is powered up by turning the main power switch (MP) to the ON position, the splash screen will display until communication and initialization is complete.

3A1705J

55

Page 55
Image 55
Graco 3A1705J important safety instructions Startup