USB Data
USB Data
USB Logs
Note
The ADM can read/write to FAT (File Allocation Table) storage devices. NTFS, used by 32 GB or greater storage devices, is not supported.
During operation, the ADM stores system and performance related information to memory in the form of log files. The ADM maintains four log files:
•Event Log
•Job Log
•Daily Log
•System Software Log
•Blackbox Log
Follow Download Procedure, page 91, to retrieve log files.
Each time a USB flash drive is inserted into the ADM USB port, a new folder named DATAxxxx is created. The number at the end of the folder name increases each time a USB flash drive is inserted and data is downloaded or uploaded.
Event Log
The event log file name is
The event log maintains a record of the last 49,182 events and errors. Each event record contains:
•Date of event code
•Time of event code
•Event code
•Event type
•Action taken
•Event Description
Event codes include both error codes (alarms, deviations, and advisories) and record only events.
Actions Taken includes setting and clearing event conditions by the system, and acknowledging error conditions by the user.
Job Log
The job log file name is
The job log maintains a record of data points based on the USB Log Frequency defined in the Setup screens. The ADM stores the last 415,413 data points for download. See Setup - Advanced Screen 3 — USB, page 46, for information on setting the Download Depth and USB Log Frequency.
•Data point date
•Data point time
•A side heat exchanger temperature
•A side boost heater temperature
•B side heat exchanger temperature
•B side boost heater temperature
•Hose temperature
•Engine coolant temperature
•A side temperature setpoint
•B side temperature setpoint
•Hose temperature setpoint
•A side pressure
•B side pressure
•Pressure setpoint
•System lifetime pump cycle counts
•Pressure, volume, and temperature units
3A1705J | 89 |