Troubleshooting
Error
Code
Error
Position
Type Name Cause Solution
Coolingfan not operating. If fan is not working check
wiring betweenCB03and
fan. If wiring is good, replace
fan.
T4CA
T4CB
T4CH
Boost A
Boost B
Hose
ALARM (T4CA or T4CB)
LPTCM Over
Temperature
(T4CH) HPTCM
Over Temperature Overheated module. Turn controller off. Wait
a few minutes. If the
condition does not clear or
regenerates consistently,
replace module.
High ambient
temperature.
Ensureambient temperature
is below 120°F(48°C)before
using the system.
T4CM MCM ALARM High MCM
Temperature
Overheated control
module.
Stop the pumps. Wait
a few minutes. If the
condition does not clear or
regenerates consistently,
replace MCM. See System
Repair manual.
Bad RTD or bad RTD
placement againstheater
rod.
Swap A and B heater volex
cables and RTD cables and
see if issue follows. If so,
replaceRTD.
T4DA
T4DB
Boost A
Boost B
ALARM High Chemical
Temperature
Bad Low Power
Temperature Control
Module.
Swap the A and B LPTCMs
and see if the issue follows
the module. If so replace
LPTCM. See system repair
manual.
Broken Fan. Check fan relay (K4) and
fuse (30 Amp ATO “F3”) on
load center board. Replace
if needed.
Plugged radiator. Replace if needed.
T4DE Heat
Exchanger
ALARM High Temperature
Coolant Outlet
High ambient
temperature.
Ensureambient temperature
is below 120°F(48°C)before
using the system.
3A1705J 83