Spraying
Spraying

The Fusion AP gun is shown.

1. Engage gun piston safety lock.
2. Close gun fluid inlet valves A and B.
3. Attach gun fluid manifold. Connect gun air line.
Open air line valve.
4. Adjust the gun air regulatoron the proportioner
control panel to desired gun air pressure. Do not
exceed 130 psi (0.2 MPa, 2 bar).
5. Set PRESSURE RELIEF/SPRAY valves (SA,
SB) to SPRAY .
SB
SA
GA GB
6. Check that heat zones are onand temperatures
are on target, seeHome screen, page 50
7. Verify that the engine temperature is at least up
to the minimum operation temperature range.
The fan will start runningwhen the engine has
reached maximum temperature.
8. Press to start motor and pumps.
9. Check fluid pressure and adjustas necessary.
10. Check fluid pressure gauges (GA, GB) to
ensure proper pressure balance. If imbalanced,
reduce pressure of higher component by
slightly turning PRESSURE RELIEF/SPRAY
valve for that component toward PRESSURE
RELIEF/CIRCULATION until gauges show
balanced pressures.
SA SB
GA GB
11. Instructions continue on next page.

3A1705J 61