Graco 3A1705J important safety instructions Error Type Name Cause Solution Code Position

Models: 3A1705J

1 106
Download 106 pages 9.62 Kb
Page 80
Image 80

Troubleshooting

 

 

 

 

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Position

 

 

 

 

P7AX

MCM

ALARM

Pressure

Pressure difference

Ensure the material flow is

P7BX

 

 

Imbalance A High

between A and B material

equally restricted on both

 

 

(P7AX)

is greater than the

material lines.

 

 

 

 

 

 

Pressure

defined value.

 

 

 

 

Pressure imbalance is

Ensure that the pressure

 

 

 

Imbalance B High

 

 

 

(P7BX)

defined too low.

imbalance value, on the

 

 

 

 

System Setup screen, is at

 

 

 

 

 

 

 

 

 

 

an acceptable maximum

 

 

 

 

 

pressure to prevent

 

 

 

 

 

unnecessary alarms and

 

 

 

 

 

abort dispenses.

 

 

 

 

Out of material.

Fill tanks with material.

 

 

 

 

Fluid leaking from heater

Check if heater

 

 

 

 

inlet rupture disk.

and PRESSURE

 

 

 

 

 

RELIEF/SPRAY valve

 

 

 

 

 

(SA or SB) are plugged.

 

 

 

 

 

Clear. Replace rupture disk.

 

 

 

 

 

Do not replace with a pipe

 

 

 

 

 

plug.

 

 

 

 

Feed system defective.

Check feed pump and hoses

 

 

 

 

 

for blockage. Check that the

 

 

 

 

 

feed pumps have the correct

 

 

 

 

 

air pressure.

P0AX

MCM

ADVISORY

Pressure

See P7AX.

 

 

 

 

Imbalance A High

 

 

P0BX

MCM

ADVISORY

Pressure

See P7BX.

 

 

 

 

Imbalance B High

 

 

T1DE

Engine

ALARM

Low Temperature

Radiator fan will not stop.

Replace fan relay. See

 

Heat

 

Coolant Outlet

 

system repair manual.

 

Exchanger

 

 

Engine thermostat is

Replace thermostat. See

 

 

 

 

stuck closed.

Perkins dealer.

80

3A1705J

Page 80
Image 80
Graco 3A1705J important safety instructions Error Type Name Cause Solution Code Position