Troubleshooting

 

 

 

 

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Location

 

 

 

 

A4NM

MCM

ALARM

High Motor

Short circuit of motor

Check wiring to the motor

 

 

 

Current

wiring.

to ensure no bare wires

 

 

 

 

 

are touching and that

 

 

 

 

 

no wires are shorted to

 

 

 

 

 

ground.

 

 

 

 

Motor will not rotate.

Replace motor. See

 

 

 

 

 

system repair manual.

 

 

 

 

Chemical pump is stuck

Repair or replace chemical

 

 

 

 

 

pump. See system repair

 

 

 

 

 

manual.

A7CH

Hose

ALARM

Unexpected

Shorted HPTCM.

Replace Module. See

 

 

 

Relay Current

 

system repair manual.

A7DA

Boost A

ALARM

Unexpected

Shorted LPTCM.

Replace Module. See

 

 

 

Heater Current

 

System Repair manual.

A7DB

Boost B

 

 

A7DH

Hose

ALARM

Unexpected

Turned off main power

Turn off heat and motor

 

 

 

Heater Current

switch with heaters and

power at ADM before

 

 

 

 

motor ON.

turning off the main power

 

 

 

 

 

switch.

 

 

 

 

Turned on hose circuit

Turn on circuit breaker

 

 

 

 

breaker with hose heat

with hose heat off.

 

 

 

 

on.

 

 

 

 

 

Failed to power off after

Power off after software

 

 

 

 

loading software.

downloaded.

 

 

 

 

Shorted HPTCM.

Replace Module. See

 

 

 

 

 

system repair manual.

A8DA

Boost A

ALARM

No Heater

Tripped circuit breaker.

Visually check circuit

A8DB

Boost B

 

Current

 

breaker for a tripped

 

 

 

condition.

 

 

 

 

 

A8DH

Hose

 

 

Loose/broken

Check heater wiring for

 

 

 

 

connection.

loose wires.

 

 

 

 

 

 

76