Graco 3A1705J Wmce MCM Alarm, Wscx ADM Advisory, Wsux USB Advisory, Wxud ADM Advisory

Models: 3A1705J

1 106
Download 106 pages 9.62 Kb
Page 88
Image 88

Troubleshooting

 

 

 

 

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Position

 

 

 

 

WMCE

MCM

ALARM

Load Center Fault

Bad Connection between

Check connection and

 

 

 

 

MCM (Port 2) and load

cables.

 

 

 

 

center board.

 

 

 

 

 

Bad load center.

Replace load center. See

 

 

 

 

 

System Repair manual.

WSCX

ADM

ADVISORY

Invalid CAN

Duplicate node on CAN

Verify LPTCM are set to A

 

 

 

Configuration

network.

and B.

WSUX

USB

ADVISORY

USB Invalid

A valid configuration file

Insert a system token into

 

 

 

Configuration

can't be found for the

the ADM and cycle the

 

 

 

 

USB.

power. Wait until the lights

 

 

 

 

 

on USB port stop flashing

 

 

 

 

 

before removing the token.

 

 

 

 

Bad ADM.

Replace ADM. See System

 

 

 

 

 

Repair manual.

WXUD

ADM

ADVISORY

USB Download

Log download failed.

Backup and reformat the

 

 

 

Error

 

USB drive. Retry download.

WXUU

ADM

ADVISORY

USB Upload Error

Custom language file

Perform normal USB

 

 

 

 

failed to upload

download and use the new

 

 

 

 

 

disptext.txt file to upload the

 

 

 

 

 

custom language.

WX00

MCM

ALARM

External Input

The alarm external input

An active alarm is being

 

 

 

 

has been driven low.

generated by the external

 

 

 

 

 

trigger. If the external alarm

 

 

 

 

 

is not configured check for a

 

 

 

 

 

short in the wiring going to

 

 

 

 

 

MCM port 7, pins 1 and 3.

88

3A1705J

Page 88
Image 88
Graco 3A1705J Wmce MCM Alarm, Wscx ADM Advisory, Wsux USB Advisory, Wxud ADM Advisory, Wxuu ADM Advisory