Component Identification

Air Control Panel

Air inlet (AA): from air line.

Air regulator 1 (AB): controls air to resin pump.

Air outlet 1 (AC): air line to resin pump.

Air pressure gauge 1 (AD): indicates air pressure to

resin pump.

Air regulator 2 (AE): for external mix guns only: con- trols catalyst atomization air. For internal mix guns only:

controls solvent flush pressure.

Air outlet 2 (AF): for external mix guns only: catalyst air

line to spray gun. For internal mix guns only: to solvent pump.

FRONT

AH

AK

Air pressure gauge 2 (AG): indicates regulator 2 air

pressure.

Air regulator 3 (AH): controls Air Assist Containment(AAC) air to spray gun.

Air pressure gauge 3 (AK): indicates AAC air pres- sure.

Air outlet 3 (AM): AAC air line to spray gun.

Air outlet 4 (AN): Chop air supply to spray gun. This outlet is plugged at the factory. Plug must be removed to install chop air.

Air Shutoff valve (AP): shuts off air to entire system.

REAR

AC

AM

AE

AD

AF

ti21338a

AP

AG AB

FIG. 1: Air Control Panel Components

ti21339a

AN

AA

Air Outlet Fitting

 

 

 

 

Details

Internal Chop

External Chop

Internal Gel

External Gel

 

 

 

 

 

Air Outlet 2 (AF)

3/8 tube

1/4 tube

3/8 tube

1/4 tube

 

 

 

 

 

Air Outlet 3 (AM)

1/4 tube

1/8 npt

3/8 tube

1/8 npt

 

 

 

 

 

Air Outlet 4 (AN)

1/2 tube

1/2 tube

Plugged

Plugged

 

 

 

 

 

Includes a 1/2 to 3/8 reducer to adapt to older chop hose bundles

12

3A2012J

Page 12
Image 12
Graco ti18524d, ti18496b, ti18526c specifications Air Control Panel