Operation

Replace DataTrak Battery or Fuse

The battery and fuse must be replaced in a non-hazardous location.

Use only the following approved replacement batter- ies. Use of an unapproved battery will void Graco’s warranty and FM and Ex approvals.

Ultralife lithium # U9VL

Duracell alkaline # MN1604

Energizer alkaline # 522

Varta alkaline # 4922

Use only a Graco-approved replacement fuse. Order Part 24C580.

Replace Battery

1.Unscrew cable from the back of the reed switch assembly. See FIG. 33.

2.Remove the cable from the two cable clips.

4.Remove two screws on back of module to access battery.

5.Disconnect the used battery and replace with an approved battery. See FIG. 34.

Replace Fuse

1.Remove the screw, metal strap, and plastic holder.

2.Pull the fuse away from the board.

3.Replace with a new fuse.

Solenoid Cable

Connection

Fuse

Sensor Cable

Connection

ti11992a

FIG. 33. Disconnect DataTrak

3.Remove DataTrak module from bracket. Take mod- ule and attached cable to a non-hazardous location.

Battery

ti11994a

FIG. 34. DataTrak Battery and Fuse Location

38

3A2012J

Page 38
Image 38
Graco ti18526c, ti18524d, ti18496b specifications Replace DataTrak Battery or Fuse, Disconnect DataTrak