Operation
38 3A2012J
Replace DataTrak Battery or Fuse

Replace Battery

1. Unscrew cable from the back of the reed switch
assembly. See F
IG
. 33.
2. Remove the cable from the two cable clips.
3. Remove DataTrak module from bracket. Take mod-
ule and attached cable to a non-hazardous location.
4. Remove two screws on back of module to access
battery.
5. Disconnect the used battery and replace with an
approved battery. See F
IG
. 34.

Replace Fuse

1. Remove the screw, metal strap, and plastic holder.
2. Pull the fuse away from the board.
3. Replace with a new fuse.
The battery and fuse must be replaced in a
non-hazardous location.
Use only the following approved replacement batter-
ies. Use of an unapproved battery will void Graco’s
warranty and FM and Ex approvals.
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Energizer alkaline # 522
Varta alkaline # 4922
Use only a Graco-approved replacement fuse. Order
Part 24C580.
F
IG
. 33. Disconnect DataTrak
ti11992a
F
IG
. 34. DataTrak Battery and Fuse Location
ti11994a
Battery
Fuse
Solenoid Cable
Connection
Sensor Cable
Connection