Setup

Solvent Flush Connections (if applicable)

NOTE: See Solvent Flush Systems component identi- fication on page 15 for connection locations.

13.Connect solvent air line from air control panel to dia- phragm pump or pressure pot air inlet.

14.Connect solvent suction tube from solvent supply tank to solvent pump fluid inlet.

15.Connect solvent line from gun hose bundle to sol- vent fluid outlet.

Gun Connections

16.For 25 ft and 35 ft hose bundles only: Place the coil of resin hose in the hose bundle on the hook sup- port located on the pole. Secure with the supplied rubber straps. The hook support should be inserted through the center of the hose coil.

17.Secure all connections on the whip-end of the hose bundle to the gun. See the gun manual listed on page 3 for detailed instructions.

Flush Before First Use

Oil left in the system at the factory can react with cata- lyst and create a fire or explosion.

Flush before first use.

Do not add catalyst to the catalyst reservoir until the system has been flushed.

Flush the system before first use to prevent contaminat- ing the resin or catalyst. See page 30.

Fill Supply Tanks

Add fluid to the solvent flush supply tank (if applicable), the catalyst supply reservoir, and the resin supply con- tainer.

3A2012J

23

Page 23
Image 23
Graco ti18526c Flush Before First Use, Fill Supply Tanks, Solvent Flush Connections if applicable, Gun Connections