Setup
3A2012J 23
Solvent Flush Connections (if applicable)
NOTE: See Solvent Flush Systems component identi-
fication on page 15 for connection locations.
13. Connect solvent air line from air con trol panel to dia-
phragm pump or pressure pot air inlet.
14. Connect solvent suction tube fro m solvent supply
tank to solvent pump fluid inlet.
15. Connect solvent line from gun hose b undle to sol-
vent fluid outlet.
Gun Connections
16. For 25 ft and 35 ft hose bundles only: Place the coil
of resin hose in the hose bundle on the hook sup-
port located on the pole. Secure with the supplied
rubber straps. The hook support should be inserted
through the center of the hose coil.
17. Secure all connections on the whip-end of the hose
bundle to the gun. See the gun manual listed on
page 3 for detailed instructions.
Flush Before First Use
Flush the system before first use to prevent contaminat-
ing the resin or catalyst. See page 30.
Fill Supply Tanks
Add fluid to the solvent flush supply tank (if applicable),
the catalyst supply reservoir, and the resin supply con-
tainer.
Oil left in the system at the factory can react with cata-
lyst and create a fire or explosion.
Flush before first use.
Do not add catalyst to the catalyst reservoir until
the system has been flushed.