Setup

Resin Pump and Optional Heater Connections

Catalyst Pump Fluid Connections

 

NOTE: See FIG. 3 on page 14.

 

11. Verify the pressure relief/recirculation valve (W) is

 

set to pressure relief (knob is horizontal).

 

M

R

W

 

 

ti21343a

 

ti18499c

P

P1

N

FIG. 9: Catalyst Pump Pressure Relief Valve

12.Connect the catalyst line from the gun hose bundle to the catalyst outlet (Z1).

S

FIG. 8

6.Verify the pressure relief/recirculation valve (P) is set to pressure relief.

7.Place a waste container below the fluid outlet then remove the pump fluid inlet cap. Drain the test oil then discard.

8.Connect resin suction hose to the resin pump 3/4 nptm fluid inlet (S). Place other end of suction hose in resin container.

9.For non-heated systems only: Connect resin hose from the gun hose bundle to the resin pump 1/4 nptf fluid outlet (R). Reducer fitting comes with Graco

hose bundle.

For heated systems only: attach resin hose from the gun hose bundle to the heater outlet. Verify fluid hose connecting resin pump outlet to heater inlet is installed and secure.

10.Connect resin recirculation hose to the pressure relief/recirculation line (P1) and route to the resin container.

22

3A2012J

Page 22
Image 22
Graco ti18496b, ti18524d, ti18526c specifications Catalyst Pump Pressure Relief Valve