Code

 

Option

Option

Type

 

Value

 

 

 

 

 

Code 128

 

 

 

 

 

 

 

0

Standard data packet, No Function code 1 in first symbol position.

 

 

 

 

 

 

1

Function code 1 in first symbol character position.

 

 

 

 

 

 

2

Function code 1 in second symbol character position.

 

 

 

 

 

 

 

Example: A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim Id

 

 

 

is transmitted as ]ClAimId

 

 

 

 

I 2 of 5

 

 

 

 

 

 

 

 

 

0

No check digit processing.

 

 

 

 

 

 

1

Reader has validated check digit.

 

 

 

 

 

 

3

Reader has validated and stripped check digit .

 

 

 

 

 

 

 

Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123

 

 

 

Codabar

 

 

 

 

 

 

 

 

0

No check digit processing.

 

 

 

 

 

 

1

Reader has checked check digit.

 

 

 

 

 

 

3

Reader has stripped check digit before transmission.

 

 

 

 

 

 

 

Example: A Codabar bar code without check digit, 4123, is transmitted as ]F04123

 

 

 

 

Code 93

 

 

 

 

 

 

 

 

0

No options specified at this time. Always transmit 0.

 

 

 

 

 

 

 

Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905

 

 

 

MSI Plessey

 

 

 

 

 

 

 

0

Single check digit checked.

 

 

 

 

 

 

1

Two check digits checked.

 

 

 

 

 

 

2

Single check digit verified and stripped before transmission.

 

 

 

 

 

 

3

Two check digits verified and stripped before transmission.

 

 

 

 

 

 

 

Example: An MSI Plessey bar code 4123, with a single check digit checked, is transmitted as

 

 

 

]M04123

 

 

 

 

D 2 of 5

 

 

 

 

 

 

 

 

0

No options specified at this time. Always transmit 0.

 

 

 

 

 

 

 

Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123

 

 

 

UPC/EAN

 

 

 

 

 

 

 

0

Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not

 

 

 

including supplemental data).

 

 

 

 

 

 

1

Two digit supplement data only

 

 

 

 

 

 

2

Five digit supplement data only

 

 

 

 

 

 

4

EAN-8 data packet.

 

 

 

 

 

 

 

Example: A UPC-A bar code 012345678905 is transmitted as ]E00012345678905

 

 

 

Bookland EAN

 

 

 

 

 

 

 

0

No options specified at this time. Always transmit 0.

 

 

 

 

 

 

 

Example: A Bookland EAN bar code 123456789X is transmitted as ]X0123456789X

 

 

 

 

Code 11

 

 

 

 

 

 

 

 

0

Single check digit.

 

 

 

 

 

 

1

Two check digits.

 

 

 

 

 

 

3

Check characters validated but not transmitted.

 

 

 

 

5 - 19