The following table indicates the behavior of the SE955 in each of the four possible parameter settings.
Standard Code 128 | UCC/EAN 128 | Effect and Example |
|
|
|
Disable | Disable | No Code 128 symbols can be read. |
|
|
|
Disable | Enable | Read only symbols with leading FNC1. |
|
|
|
|
| Examples: |
|
|
|
|
| FNC1ABCDFNC1E are read as ABCD29E |
|
| AFNC1BCDFNC1E are read as ABCD29E |
|
| FNC1FNC1ABCDFNC1E are read as ABCD29E |
|
| ABCDFNC1E cannot be read |
|
| ABCDE cannot be read |
|
|
|
Enable | Disable | Read only symbols without leading FNC1. |
|
|
|
|
| Examples: |
|
|
|
|
| FNC1ABCDFNC1E cannot be read |
|
| AFNC1BCDFNC1E cannot be read |
|
| FNC1FNC1ABCDFNC1E cannot be read |
|
| ABCDFNC1E is read as ABCD29E |
|
| ABCDE is read as ABCDE |
|
|
|
Enable | Enable | Read both types of symbols. |
|
|
|
|
| Examples: |
|
|
|
|
| FNC1ABCDFNC1E are read as ABCD29E |
|
| AFNC1BCDFNC1E are read as ABCD29E |
|
| FNC1FNC1ABCDFNC1E are read as ABCD29E |
|
| ABCDFNC1E is read as ABCD29E |
|
| ABCDE is read as ABCDE |
|
|
|
Set this parameter by scanning either of the bar codes shown below.
* Enable
Disable
Lengths for Code 128
No length setting is required for Code 128. The default setting is Any Length.
4 - 34