Transmit AIM Code ID Character
Each AIM Code Identifier contains the three character string ]cm where:
]= Flag Character (ASCII 93) c= Code Character
A | Code 39 |
|
|
C | Code 128 |
|
|
E | UPC/EAN |
|
|
F | Codabar |
|
|
G | Code 93 |
|
|
H | Code 11 |
|
|
I | Interleaved 2 of 5 |
|
|
M | MSI Plessey |
|
|
S | D2 of 5, IATA 2 of 5 |
|
|
X | Code 39 Trioptic, Bookland EAN |
|
|
e | GS1 DataBar (RSS) |
|
|
m= Modifier Character
The modifier character is the sum of the applicable option values based on the following table.
Code |
| Option | Option |
Type |
| Value | |
|
| ||
|
|
|
|
Code 39 |
|
| |
|
|
|
|
|
| 0 | No Check character or Full ASCII processing. |
|
|
|
|
|
| 1 | Reader has checked one check character. |
|
|
|
|
|
| 3 | Reader has checked and stripped check character. |
|
|
|
|
|
| 4 | Reader has performed Full ASCII character conversion. |
|
|
|
|
|
| 5 | Reader has performed Full ASCII character conversion and checked one check character. |
|
|
|
|
|
| 7 | Reader has performed Full ASCII character conversion and checked and stripped check |
|
|
| character. |
|
|
|
|
|
|
| Example: A Full ASCII bar code with check character W,A+I+MI+DW, is transmitted as ]A7AimId |
|
|
| where 7 = (3+4). |
|
|
| |
Trioptic Code 39 |
| ||
|
|
|
|
|
| 0 | No option specified at this time. Always transmit 0. |
|
|
|
|
|
|
| Example: A Trioptic bar code 412356 is transmitted as ]X0412356 |
|
|
| |
Code 128 |
| ||
|
|
|
|
|
| 0 | Standard data packet, No Function code 1 in first symbol position. |
|
|
|
|
|
| 1 | Function code 1 in first symbol character position. |
|
|
|
|
|
| 2 | Function code 1 in second symbol character position. |
|
|
|
|
|
|
| Example: A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim |
|
|
| Id is transmitted as ]ClAimId |
|
|
|
|
4 - 12