Code

Option

Option

Type

Value

 

 

 

 

QR Code

 

 

 

 

 

0

Model 1 symbol.

 

 

 

 

1

Model 2 symbol, ECI protocol not implemented.

 

 

 

 

2

Model 2 symbol, ECI protocol implemented.

 

 

 

 

3

Model 2 symbol, ECI protocol not implemented, FNC1 implied in first position.

 

 

 

 

4

Model 2 symbol, ECI protocol implemented, FNC1 implied in first position.

 

 

 

 

5

Model 2 symbol, ECI protocol not implemented, FNC1 implied in second position.

 

 

 

 

6

Model 2 symbol, ECI protocol implemented, FNC1 implied in second position.

 

 

 

According to AIM standards, a UPC with supplemental bar code is transmitted in the following format:

]EO (UPC chars) (terminator) ]E2 (supplemental) (terminator)

Therefore, a UPC with two supplemental characters, 01234567890510, is transmitted to the host as a 21-character string, ]E00012345678905]E110.

5 - 21