Code | Option | Option | |
Type | Value | ||
| |||
|
|
|
Interleaved 2 of 5
0No check digit processing.
1Reader has validated check digit.
3 | Reader has validated and stripped check digit . |
| Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123 |
Codabar
0No check digit processing.
1Reader has checked check digit.
3Reader has stripped check digit before transmission.
Example: A Codabar bar code without check digit, 4123, is transmitted as ]F04123
Code 93
| 0 | No options specified at this time. Always transmit 0. |
|
|
|
|
| Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905 |
|
|
|
MSI (Plessey) |
| |
|
| |
| 0 | Single check digit checked. |
|
|
|
| 1 | Two check digits checked. |
|
|
|
| 2 | Single check digit verified and stripped before transmission. |
|
|
|
| 3 | Two check digits verified and stripped before transmission. |
|
|
|
|
| Example: An MSI Plessey bar code 4123, with a single check digit checked, is transmitted as |
|
| ]M04123 |
|
|
|
Discrete 2 of 5 |
| |
|
| |
| 0 | No options specified at this time. Always transmit 0. |
|
|
|
|
| Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123 |
|
|
|
UPC/EAN |
| |
|
| |
| 0 | Standard packet in full EAN country code format, which is 13 digits for |
|
| including supplemental data). |
|
|
|
| 1 | Two digit supplement data only |
|
|
|
| 2 | Five digit supplement data only |
|
|
|
| 4 | |
|
|
|
|
| Example: A |
|
|
|
Bookland EAN |
| |
|
|
|
0No options specified at this time. Always transmit 0.
Example: A Bookland EAN bar code 123456789X is transmitted as ]X0123456789X
According to AIM standards, a UPC with supplemental bar code is transmitted in the following format: ]EO (UPC chars) (terminator) ]E2 (supplemental) (terminator)
Therefore, a UPC with two supplemental characters, 01234567890510, is transmitted to the host as a
4 - 13