Figure 66 Setting the time zone

3.Configure the time zone and daylight saving time as described in Table 16.

4.Click Apply.

Table 16 Configuration items

Item

Description

Time Zone

Set the time zone for the system.

 

 

 

Adjust the system clock for daylight saving time changes, which means adding one hour to

 

the current system time.

 

Click Adjust clock for daylight saving time changes to expand the option, as shown

 

in Figure 67. You can configure the daylight saving time changes in the following ways:

Adjust clock for

Specify that the daylight saving time starts on a specific date and ends on a specific date.

daylight saving

The time range must be greater than one day and smaller than one year. For example,

time changes

configure the daylight saving time to start on August 1st, 2006 at 06:00:00 a.m., and

 

end on September 1st, 2006 at 06:00:00 a.m.

 

Specify that the daylight saving time starts and ends on the corresponding specified days

 

every year. The time range must be greater than one day and smaller than one year. For

 

example, configure the daylight saving time to start on the first Monday in August at

 

06:00:00 a.m., and end on the last Sunday in September at 06:00:00 a.m.

Figure 67 Setting the daylight saving time

Date and time configuration example

In this example, Device A is the firewall.

Network requirements

The local clock of Device A is set as the reference clock, with the stratum of 2. Device B operates in client mode, and uses Device A as the NTP server.