HP 3162 manual Table C-7. Communication Port Configuration Options 2

Models: 3162

1 199
Download 199 pages 36.77 Kb
Page 116
Image 116

Configuration Options

Table C-7. Communication Port Configuration Options (2 of 3)

Data Rate:

9.6

 

 

 

 

1.2

2.4

4.8

9.6

14.4

19.2

38.4

 

 

 

 

 

 

 

Configures the bit rate for the communication port.

1.2– Sets the bit rate to 1200 bps (for asynchronous operation only).

2.4– Sets the bit rate to 2400 bps.

4.8– Sets the bit rate to 4800 bps.

9.6– Sets the bit rate to 9600 bps.

14.4– Sets the bit rate to 14,400 bps.

19.2– Sets the bit rate to 19,200 bps.

38.4– Sets the bit rate to 38,400 bps.

NOTE: This configuration option is not available if the communication port is configured for synchronous operation and the clock source is external.

Character Length: 8 7 8

Configures the character length (7 or 8 bits) for the communication port.

NOTES: – This configuration option must be set to 8 if the communication port is used as the network communication link.

This configuration option is not available if the communication port is configured for synchronous operation.

Parity: None

None Even Odd

Configures the parity (none, even, or odd) for the communication port.

NOTE: This configuration option is not available if the communication port is configured for synchronous operation.

Stop Bits: 1 1 1.5 2

Configures the number of stop bits (1, 1.5, or 2) for the communication port.

NOTE: This configuration option is not available if the communication port is configured for synchronous operation.

Ignore Control Leads: Disable

Disable DTR

Specifies whether the DSU/CSU ignores the state of the Data Terminal Ready (DTR) input to the communication port.

Disable – The control leads are treated in the standard manner.

DTR – DTR is ignored.

NOTE: This configuration option is not available if the communication port is configured for synchronous operation.

Password Required: Disable

Enable Disable

Activates a password prompt that prevents access until a password is entered.

Enable – Prompts the communications port user to enter a password.

Disable – Does not require a password.

C-18