SNMP MIB Objects

Output Signal Table, RS-232-like MIB

This object contains entries for the output signals that can be asserted by the unit for each of the synchronous data ports.

Output Signal Table – “rs232OutSigName” (rs232OutSigEntry 2)

This object contains the identification of a hardware output signal. Only the following values are supported by the DSU/CSU.

Hcts(1) – Clear-To-Send.

Hdsr(4) – Data Set Ready.

Output Signal Table – “rs232OutSigState” (rs232OutSigEntry 3)

This object contains the current signal state. Only the following values are supported by the DSU/CSU.

Hon(2) – The signal is asserted.

Hoff(3) – The signal is not asserted.

Output Signal Table – “rs232OutSigChanges” (rs232OutSigEntry 4)

This object is not supported by the DSU/CSU.

Generic-Interface MIB Extensions (RFC 1229)

This generic-interface MIB is an experimental MIB that provides extensions to the generic interface group defined in MIB II. This MIB describes three tables:

HGeneric Interface Extension Table

HGeneric Interface Test Table

HGeneric Receive Address Table

Only the generic interface test table is supported by the DSU/CSU. This table is supported for the network interface only.

3162-A2-GB20-40

August 2000

E-21