Monitoring and Testing

Table 5-1. Self-Test Results

Message

Description

 

 

Alarm Fail

The unit failed to transmit AIS or to detect an Yellow alarm.

 

 

B8ZS/LOS Fail

The unit failed to encode data properly or to detect Loss Of

 

Signal.

 

 

CPU Fail

The central processing unit failed internal testing.

 

 

Device Fail

One or more of the unit’s integrated circuit chips failed to pass

 

internal device level testing.

 

 

DSU Fail

The unit failed to internally loop data on the DSU.

 

 

DSU Port n Fail

Port’s integrated circuitry failed to pass device internal testing.

 

 

DTE T1 Fail

The unit failed to internally loop data on the DTE T1 (DSX-1)

 

circuit.

 

 

Failure xxxxxxxx

An 8-digit hexadecimal failure code is provided for service

 

personnel.

 

 

Memory Fail

The unit failed program checksum verification.

 

 

Modem fail

Unit failed to internally loop data through the modem circuit.

 

 

Network T1 Fail

The unit failed to internally loop data on the network T1 circuit.

 

 

Passed

No problems were found during power-on.

 

 

Unknown Exp Dev

The unit is not able to recognize the expansion device connected

 

to the main circuit card.

 

 

5-2

August 2000

3162-A2-GB20-40