Monitoring and Testing

Troubleshooting

The DSU/CSU is designed to provide you with trouble-free service. However,

Table 5-8 gives you some direction if a problem occurs.

For problems other than those listed in the table, please contact your service representative.

Table 5-8. Troubleshooting (1 of 2)

Symptom

Possible Cause

Solutions

 

 

 

 

 

No power

1.

The power module is not

1.

Check the power module

 

 

securely attached.

 

attachment.

 

2.

The wall receptacle has

2.

Check the wall

 

 

no power.

 

receptacle power by

 

 

 

 

plugging in some

 

 

 

 

equipment that is known

 

 

 

 

to be working.

 

 

 

Power-On Self-Test fails

The DSU/CSU has

Contact your service

 

detected an internal

representative.

 

hardware failure.

 

 

 

 

 

 

 

Message LOS at

1.

Network cable problem.

1.

Check that the network

Network appears

 

 

 

cable is securely

 

 

 

 

attached at both ends.

 

2.

No signal is being

2.

Check the far-end status.

 

 

transmitted at the far

 

 

 

 

end.

 

 

 

3.

Facility problem.

3.

Contact your facility

 

 

 

 

provider.

 

 

 

 

 

Message LOS at DTE

1.

1.DTE Drop/Insert

1.

Check that the DTE

appears

 

(DSX-1) cable problem.

 

Drop/Insert (DSX-1)

 

 

 

 

cable is securely

 

 

 

 

attached at both ends.

 

2.

No signal being

2.

Check the DTE status.

 

 

transmitted from the

 

 

 

 

DTE.

 

 

 

 

 

 

 

Message OOF at

1.

Incompatible framing

1.

Check that the framing

Network appears

 

format between the

 

format for the network

 

 

network and the

 

interface is correct.

 

 

DSU/CSU.

 

 

 

2.

Network cabling

2.

Check that the network

 

 

problem.

 

cable is securely

 

 

 

 

attached at both ends.

 

3.

Facility problem.

3.

Contact your facility

 

 

 

 

provider.

 

 

 

 

 

3162-A2-GB20-40

August 2000

5-15

Page 79
Image 79
HP 3162 manual Troubleshooting 1 Symptom Possible Cause Solutions