HP 3162 manual Health and Status Messages 2 Description

Models: 3162

1 199
Download 199 pages 36.77 Kb
Page 68
Image 68

Monitoring and Testing

Table 5-2. Health and Status Messages (2 of 2)

Message

Description

 

 

OOF at DTE

An Out Of Frame condition has been detected on the DTE

 

Drop/Insert (DSX-1) interface. The condition is cleared when a

 

reframe occurs.

 

 

OOF at Network

An Out Of Frame condition (2 out of 4 frame synchronization bits

 

in error) has been detected on the network interface. The

 

condition is cleared when a reframe occurs.

 

 

OOF at Port n

An Out Of Frame condition has been detected on data port Port n

 

(where n is the port number). This condition only occurs if the

 

synchronous data port’s Embedded Data Link (EDL) is enabled.

 

 

Primary Clock

The primary clock has failed. Timing for the DSU/CSU is provided

Failed

by the internal clock.

 

 

System Operational

This message only appears if there are no valid alarm or status

 

messages.

 

 

Yellow at DTE

A Yellow Alarm signal is being received by the DTE Drop/Insert

 

(DSX-1) interface.

 

 

Yellow at Network

A Yellow Alarm signal is being received by the network interface.

 

 

5-4

August 2000

3162-A2-GB20-40

Page 68
Image 68
HP 3162 manual Health and Status Messages 2 Description