4.Remove one grounding screw and wire (callout 3), and disconnect three cable connectors (callout 4).

3

4

Figure 5-59Removing the ADF assembly (3 of 3)

5.Remove the ADF assembly by lifting it up and lifting the rear hinges out of their sockets. NOTE: Make sure you calibrate the scanner when necessary.

82 Chapter 5 Removal and replacement