Table 6-1Control-panel messages (continued)

Control panel message

Description

Recommended action

and then on again as you install each device.

10. Replace the component that caused the error message.

51.XY ERROR To continue turn off then

A temporary error has occurred.

1.

Turn the device off, and then turn the

on

 

 

device on.

 

 

2.

If the message persists, replace the

 

 

 

formatter.

52.XY ERROR To continue turn off then A temporary error has occurred. on

1.Turn the device off, and then turn the device on.

2.If the message persists, replace the formatter.

54.XX ERROR To continue turn off then A temporary error has occurred. on

1.Turn the device off, and then turn the device on.

2.If the message persists, replace the formatter.

55.XX DC CONTROLLER ERROR To

The device is not communicating with the

1.

Turn the device off, and then turn the

continue turn off then on

formatter.

 

device on.

 

 

2.

Reseat the formatter.

 

 

3.

Check to find out if an RFU is available.

 

 

 

If it is, perform the RFU.

 

 

4.

If the error persists, replace the

 

 

 

formatter. See Formatter cage

 

 

 

on page 49.

 

 

 

 

56.XX ERROR To continue turn off then

A temporary error has occurred.

1.

Turn the device off, and then turn the

on

 

 

device on.

 

 

2.

Reseat the formatter.

 

 

3.

Check to find out if an RFU is available.

 

 

 

If it is, perform the RFU.

 

 

4.

If the error persists, replace the

 

 

 

formatter. See Formatter cage

 

 

 

on page 49.

 

 

 

 

57.XX ERROR To continue turn off then

A temporary error has occurred.

1.

Turn the device off, and then turn the

on

 

 

device on.

 

 

2.

If the error persists, check the fan

 

 

 

connectors and then make sure that the

 

 

 

fan blades can move freely.

 

 

3.

Listen for the fans to operate while the

 

 

 

device is initializing. If the fan does not

 

 

 

operate during the initialization

 

 

 

sequence, replace it.

 

 

 

 

59.XY ERROR To continue turn off then

A temporary error has occurred.

1.

Turn the device off, and then turn the

on

 

 

device on.

 

 

2.

If the message persists, replace the

 

 

 

formatter.

 

 

 

 

ENWW