HP OneView for VMware vCenter/Operations Manager/Log Insight manual Storage Array capacity

Models: OneView for VMware vCenter/Operations Manager/Log Insight

1 92
Download 92 pages 8.99 Kb
Page 54
Image 54

Figure 26 Storage Array capacity

If there is not enough space available in the selected storage pool, a message is displayed in the Warnings box.

RAID Level: Select a RAID level for the new datastores. The wizard lists all RAID levels supported by the selected storage pool.

4.Click Next.

The Add Datastores – Specify New Names window opens. See Figure 27 (page 54). Figure 27 Add Datastores – Specify New Names window

5.Enter the following information:

New Datastore Names: Enter the base name for the new datastores. The # symbol is required and represents the numeric sequence for the new datastore names. In the generated datastore names, the # symbol is replaced with a number.

Where # is numeric and starts at: Enter the start value for the numeric sequence of datastore names. The default values are as follows:

Number of datastores to add

Default start value for numeric sequence

1–9

1

10–99

01

100–999

001

The Generated Names box shows the names of the datastores that will be created.

54 Provisioning storage

Page 54
Image 54
HP OneView for VMware vCenter/Operations Manager/Log Insight manual Storage Array capacity