HP OneView for VMware vCenter/Operations Manager/Log Insight manual Alarms

Models: OneView for VMware vCenter/Operations Manager/Log Insight

1 92
Download 92 pages 8.99 Kb
Page 71
Image 71

HP SNMP agent and HP CIM provider events

HP Insight Control for vCenter registers with HP SNMP agents and HP CIM providers to receive traps from HP SNMP agents and indications from HP CIM providers as they occur. Events created based on these traps and indications fit into the defined vCenter Server categories.

Event type

Event severity

vCenter Server event category

HP SNMP agents or HP CIM providers

Normal or Information

Info

HP SNMP agents or HP CIM providers

Warning or Minor

Warning

HP SNMP agents or HP CIM providers

Major or Critical

Error

These events contain the following information:

Event source

Event name

Event category

Event description

Alarms

When an Insight Control for vCenter event is delivered to vCenter Server, the overall host status changes based on the corresponding event category or the host status. An alarm is triggered when the changes to the host status meet the criteria assigned by the administrator.

Event category

Overall host status

Informational

Green

Warning

Yellow

Error

Red

Four Insight Control for vCenter events can cause alarms in vCenter Server:

Alarms associated with the HP server SNMP traps

These alarms can be triggered by any event generated from an SNMP trap. The alarm states are controlled by the event category.

Alarms associated with the HP server WBEM indications

These alarms can be triggered by any event generated from a WBEM indication. The alarm states are controlled by the event category.

Alarms associated with HP BladeSystem fan zones

These alarms are triggered by an HP BladeSystem subsystem event. The alarm states are controlled by the type (severity) of the event. The alarms are triggered on all HP ProLiant and BladeSystem servers in the affected fan zone.

Alarms associated with HP BladeSystem power subsystem

These alarms are triggered by an HP BladeSystem power subsystem event. The alarm states are controlled by the type (severity) of the event. The alarms are triggered on all HP ProLiant and BladeSystem servers in the affected enclosure.