IBM 6645, 6644, 6646 manual Dimm

Models: 6644 6646 6645

1 173
Download 173 pages 20.63 Kb
Page 78
Image 78

Table 2-2 BIOS Error Beeps List

NOTE: To diagnose a problem, first find the BIOS error beeps in left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause.

BIOS Error Beeps

Action/FRU

 

 

1-3-2

Insert the memory modules

1st 64K RAM Parity Test

in the DIMM sockets

Error

properly, then reboot the

 

system.

 

Memory module. See the

 

“Step 005” of “Memory” on

 

page 64 to replace memory

 

module.

 

System board

 

 

1-3-2

Insert the memory modules

Wrong Data Gets From

in the DIMM sockets

DIMM’s SPD

properly, then reboot the

 

system.

 

DIMM.

 

System board.

 

 

1-3-2

DIMM

Incorrect DRAM Type

 

 

 

2-1-1

Hard disk drive

Slave DMA Register Test In-

System board

Progress or Error

 

 

 

2-1-2

Hard disk drive

Master DMA Register Test

System board

In-Progress or Error

 

 

 

2-1-3

Hard disk drive

Master Interrupt Mask

System board

Register Test Error

 

 

 

2-1-4

Hard disk drive

Slave Interrupt Mask

System board

Register Test Failure

 

 

 

2-2-2

System board

Keyboard Controller Test

 

Error

 

 

 

2-3-2

Enter BIOS Setup and load

Screen Memory Test In-

the default settings.

Progress or Error

System board.

 

 

46 IBM Desktop System HMM