Table 2-1 POST Error Codes and Messages List
NOTE: To diagnose a problem, first find the BIOS error messages or codes in left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause.
BIOS Error Codes, | Action/FRU | |
Messages | ||
| ||
|
| |
1780 | Reconnect hard disk cables. | |
Fixed Disk Configuration | Hard disk drive | |
Error | System board | |
|
| |
1780 | Reconnect hard disk cables | |
Fixed Disk 0 Error | Enter BIOS setting to load | |
1780 | default settings: | |
Fixed Disk Error | 1. Proper speed for | |
1781 | processor. Speed should | |
be a multiple of the | ||
Fixed Disk 1 Error | ||
original processor. | ||
1782 | ||
Hard disk drive | ||
Fixed Disk 2 Error | ||
System board | ||
1783 | ||
| ||
Fixed Disk 3 Error |
| |
|
| |
1800 | Run Setup, verify PCI | |
No More IRQs available | Run Diagnostics | |
1880 | PCI adapter card | |
No More IRQs available |
| |
|
| |
1801 | Check Setup | |
No More Room for Option | Run Diagnostics | |
ROM | Adapter Cards | |
1881 | Make sure BIOS is at latest | |
No More Room for Option | level | |
ROM | System board | |
|
| |
1802 | Check Setup | |
No More I/O Space | Run Diagnostics | |
Available | Adapter Cards | |
1882 | Make sure BIOS is at latest | |
No More I/O Space | level | |
Available | System board | |
|
|
42 IBM Desktop System HMM