Table 2-3 Error Symptoms List (Continued)

NOTE: To diagnose a problem, first find the error symptom in the left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/ FRU listed in right column is the most likely cause.

Error Symptoms

Action/FRU

 

 

USB device failed.

Ensure that the USB device

 

is properly installed.

 

Refer to the service manual

 

for the USB device.

 

USB device.

 

USB device cable.

 

System board.

 

 

USB device problems.

Refer to the service manual

 

for the USB device.

 

 

Diagnostic Program

 

 

Diagnostics programs

Reboot the system from the

cannot be executed.

diagnostics diskette.

 

Load default settings.

 

Diagnostics diskette.

 

Memory module.

 

System board.

 

 

Missing diagnostics file(s).

Diagnostics diskette.

 

 

Keyboard

Some or all keys on

“Keyboard” on page 65.

keyboard do not work.

 

 

 

Power Supply

 

 

Pressing power switch does

Power switch cable

not turn off the system.

assembly

(Only unplug power cord

“Power Supply” on page 68

from electrical outlet can

 

turn off system.)

 

 

 

Pressing power switch does

Ensure the power override

not turn on system.

switch (situated at the back

 

of the machine, just above

 

the connector for the power

 

cable) is not set to off.

 

Power switch cable

 

assembly.

 

 

Check Procedures 53