10 HOW TO USE TIME CODE

10-3 TIME CODE RECORDING

Recording the time code data output from the external time code generator

Externally generated time code can be recorded after being regenerated with the time code data output from the built-in time code generator.

10 HOW TO USE TIME CODE

10-4 TIME CODE PLAYBACK

Time code is output through the rear panel [TC OUT] and [VIDEO OUT] connectors during playback. VITC time code with the time code data superimposed on the video signal is output through the [VIDEO OUT-LINE] connector. Sub time code is output through the [VIDEO OUT-LINE] connector as VITC time code when menu switch No. 451 <VITC OUT SELECT> is set to “SUB TC”. Only the main time code is output through the [TC OUT] connector.

AUDIO INPUT / AUDIO MONITOR SELECT

SDI CH1 CH2 CH3 CH4

AES/EBUL CH1 CH2 CH3 CH4

ANALOGR CH1 CH2 CH3 CH4

 

VIDEO CASSETTE RECORDER

BR-D95U

 

 

 

 

 

 

POWER

 

 

SIF

 

 

 

 

 

 

LINE

 

 

ON

I

 

 

CPN

COMPONENT DIGITAL

 

OFF

O

 

 

 

 

 

 

 

 

Variable Motion

 

 

 

 

 

 

 

TIME CDOE

 

 

 

 

DF

INT

FREE PRESET

 

 

 

NDF EXT

REC

REGEN

 

 

 

RF HID GND

OFF

8

ON

 

 

 

SERVICE USE ONLY

ON

4

OFF

 

 

 

 

CF

(625)

ON SCREEN

 

 

 

 

 

 

 

TIME CDOE

 

 

 

 

DF

INT

FREE PRESET

 

Front sub panel

 

 

 

 

REC REGEN

 

 

 

 

NDF

EXT

 

 

 

 

 

 

 

[COUNTER] button

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO CASSETTE RECORDER

BR-D95U

AUDIO INPUT / AUDIO MONITOR SELECT

 

 

 

 

 

 

 

POWER

SDI

CH1

CH2

CH3

CH4

SIF

 

 

 

 

 

 

 

AES/EBU

CH1

CH2

CH3

CH4

LINE

 

 

 

 

 

ON

I

L

 

 

 

 

 

 

 

ANALOG

CH1

CH2

CH3

CH4

CPN

 

 

COMPONENT DIGITAL

 

 

OFF

O

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable Motion

 

 

CH1

CH2

 

CH3

CH4/TRACKING

 

 

 

 

 

 

 

 

 

 

 

 

 

CTL TC UB DF SERVO CF GEN 16:9 AP

525

CONDITION

COUNTER

RESET

VCON

REMOTE

 

 

 

 

 

 

AUTO OFF P.READ V.VAR PB/EE REMOTE

625

 

UB

 

 

 

 

 

 

 

 

 

 

 

 

MENU

SET

HOLD

PB

 

 

 

 

 

 

 

 

 

PB/EE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STILL

 

 

 

 

 

H

M

 

S

 

F

 

 

 

 

 

 

 

 

 

ASSEM

VIDEO

DA1

DA2

DA3

DA4

EJECT

REC

PLAY

PAUSE/STILL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-1

X1

PHONES

CH1

CH2 REC CH3

CH4

TRACKING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

ENTRY

OUT

INSERT

 

TC

TOP

 

VIDEO

AUDIO

 

 

 

 

PULL FOR VARIABLE

 

METER MODE

CANCEL PREVIEW

AUTO EDIT

PREROLL

STAND BY

REW

STOP

FF

 

 

PULL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PULL

RELEASE

 

PLAY

 

SHIFT

 

REVIEW

 

 

USER

SERVO/SYS

TIME CODE

ON SCREEN

OTHERS

 

RELEASE

 

 

 

 

 

 

REV

FWD

[PLAY] button

Notes

Drop/Non-drop Frame mode selection (NTSC only)

Automatically selected according to the mode of the received time code (Drop Frame or Non-drop Frame).

Regeneration operation

When time code is being regenerated with input time code, the built-in time code generator stops counting when no time code is input.

In the Play mode, time code regeneration is based on the playback time code value.

Inserting time code

If only time code data is being inserted, record it on the main time code. It is not possible to insert it in the sub time code.

1.Front sub panel switch setting

Select the External Time Code Generator mode by setting the [INT/EXT] switch to “EXT”.

The [FREE/REC] and [PRESET/REGEN] switch settings are not necessary.

Select the Counter Display or On-screen Display mode to TC or UB with the [COUNTER] and [SHIFT] buttons.

2.Menu switch setting

Select the external time code to be regenerated.

Menu switch No. 409 <EXT REGEN TC> (Initial setting: LTC (0))

LTC (0): Regenerates the LTC time code input through the rear panel [TC IN] connector.

Input LTC time code should be regenerated (matched in terms of sync and phase) with video signals. Make sure you input an external sync signal to the feeding equipment.

VITC (1): Regenerates the VITC time code superimposed on the video signal input through the rear panel VIDEO IN connector.

User bit data selection

Menu switch No. 457 <UB PRESET AUTO> (initial setting OFF (0))

OFF (0): User bits regenerated by the time code generator of this unit is recorded.

ON (1): The user bit auto preset function is activated and the user bit data stored in the built-in memory is recorded.

Select the sub time code.

Menu switch No. 450 <SUB TC (VITC) REC> (Initial setting: ON(1))

OFF (0): “00:00:00:00” is always recorded on the sub time code.

ON (1): Records the input VITC time code in the sub time code.

3.Record the time code.

Press the [PLAY] button while pressing the [REC] button. [The selected time code will be recorded.

When you are using this deck as a player, the recording time code may not be regenerated when you output embedded audio (SERIAL V/A OUT) signals to the BR-D750U, BR-D85U or BR-D80U. In this case, set menu switch No. 237 <EMBEDDED AUDIO> to “OFF”.

On-screen display of sub time code

Sub time code is displayed with the main time code when menu switch No. 451

<VITC OUT SELECT> is set to “SUB TC (0)”.

Setting

1.Front panel switch setting

Select a Counter Display mode to TC or UB with the [COUNTER] and [SHIFT] buttons.

2.Menu switch setting

For VITC time code output, select a line to be added to the video signal.

Menu switch No. 400 <VITC LINE-1 SELECT> (Initial setting: NTSC 16 LINE/PAL 19 LINE)

Menu switch No. 401 <VITC LINE-2 SELECT> (Initial setting: NTSC 18 LINE/PAL 21 LINE )

Select VITC time code output through the [VIDEO OUT] connector. Menu switch No. 451 <VITC OUT SELECT>

SUB TC (0)

: Outputs the VITC time code recorded in the sub time code.

TC (1)

: Outputs the time code recorded in the main time code.

OFF

: VITC time code is not output from the [VIDEO OUT]

 

connector.

Factory setting : TC (1)

Select the Time Code Output mode during search. Menu switch No. 452 <SEARCH LTC>

OFF (0)

: Outputs time code through the [TC OUT] connector during search

 

at X1.

ON (1)

: Outputs time code through the [TC OUT] connector during search

 

at all speeds. Continuous time code is not available.

3.Play back the time code. Press the [PLAY] button.

[The selected time code is played back.

TCR or UBR is shown with the on-screen time code data.

LTC time code is output from the [TC OUT] connector.

Main or sub time code selected with menu switch No. 451 <VITC OUT SELECT> is superimposed on video signals and output to the line selected with menu switch No. 400 and No. 401 from the [VIDEO OUT] connector.