JVC DLA-G150CLU manual RS-232C external control, No.51931 1-39, Communication Specifications

Models: DLA-G150CLU DLA-G150CLE

1 80
Download 80 pages 43.8 Kb
Page 39
Image 39
No.51931

No.51931

1-39

RS-232C external control

By connecting a computer to the RS-232C terminal, you can control the projector. Use a reverse connection cable as the RS- 232C connection cable.

The commands to control the projector and the response data against the received commands are explained here.

For further information, please consult the dealer where you purchased your projector or consult the Service Center.

1. Communication Specifications

The communication specifications are as follows:

Baud rate

9600bps / 19200bps*

 

 

Data length

8 bits

 

 

Parity

None

 

 

Stop bit

1 bit

 

 

Flow control

None

 

 

* Factory set value. To change the value, refer to “Setting and Adjusting Other Functions (OPTIONS)” on page 54.

2. Command Format

2-1. Command data format (from the computer to the projector)

When sending a control command, use the following data format.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

 

ID

 

SP

 

Command

SP

 

 

Parameter

 

CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header: Designates the head of data and the kind of data.

 

 

 

 

 

 

“!” (21h): Control command to the projector

 

 

“?” (3Fh): Query to the projector (Asking command)

 

ID:

“1” (fixed)

 

 

 

 

 

 

 

 

 

 

 

SP:

Designates the delimiter for ID, Command, and Parameter. (20h)

 

CR:

Designates the terminal of the data. (0Dh)

 

 

 

 

 

* [

] is not necessary when Asking command.

 

 

 

 

 

 

 

2-2. Response data format (from the projector to the computer)

Upon executing the received control command, the projector sends back the following response data to the computer.

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

 

ID

 

SP

 

Normal Termination Status

SP

 

Parameter

 

CR

 

 

 

 

 

 

 

 

 

 

 

 

Header: Designates the head of data.

 

 

 

 

 

 

“@” (40h): Fetches data from the projector.

 

 

 

 

 

ID:

“1” (fixed)

 

 

 

 

 

 

 

 

 

SP:

Designates the delimiter for ID, Command, and Parameter (20h)

 

 

 

 

Normal Termination Status: “0” (30h)

 

 

 

 

 

CR:

Designates the terminal of the data (0Dh)

 

 

 

 

 

74

RS-232C external control

2-3 Parameters used for the data format

The following three kinds of parameters are prepared for the control command and response data.

(1) Numeric value

Designates the 2-byte hexadecimal value with the sign as the 4-digit (byte) characters.

Designation allowable range: “8000” to “7FFF”

(2) ON/OFF

Designates the status (ON/OFF) of the projector, such as POWER and HIDE.

Character

Hex.

Meaning

 

 

 

“0”

30

OFF

 

 

 

“1”

31

ON

 

 

 

(3)Special parameters

Input switching parameters:

Character

Hex.

Meaning

 

 

 

“0”

30

Y/C

 

 

 

“1”

31

VIDEO

 

 

 

“2”

32

COMP

 

 

 

“3”

33

PC1

 

 

 

“4”

34

PC2

 

 

 

“5”

35

DVI

 

 

 

Operation mode

parameters:

 

Character

Hex.

Meaning

 

 

 

“0000”

30h, 30h, 30h, 30h

Stand-by mode

 

 

 

“0001”

30h, 30h, 30h, 31h

Power-on mode

 

 

 

“0002”

30h, 30h, 30h, 32h

Cool-down mode

 

 

 

“0004”

30h, 30h, 30h, 34h

Warning mode

 

 

 

3. Control command table

The control commands that can be sent from the computer are as follows:

Function

 

 

Command

 

 

Asking

 

 

 

 

Kind

of data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

ON

ELSE

 

Numeric

 

Value

ON/OFF

 

Special Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATE

U0F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIDE

 

U00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Right Left rev.

 

 

U17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top Bottom inv.

 

U18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keystone

 

U40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

U1A

 

 

 

 

 

Y/C, VIDEO, PC1, PC2,

 

 

 

 

 

 

 

 

 

COMP, DVI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation mode

 

Z03

 

 

 

 

 

Stand-by, Power-on,

 

 

 

 

 

 

 

 

 

Cool-down, Warning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Keystone: Numeric value can range from “FF80” to “0080”*Operation mode: Only Asking command is possible