JVC DLA-G150CLU No.51931 1-73, Cleaning and Replacing the Filter Cover, Troubleshooting, Cautions

Models: DLA-G150CLU DLA-G150CLE

1 80
Download 80 pages 43.8 Kb
Page 73
Image 73
No.51931

No.51931

1-73

Cleaning and Replacing the Filter Cover

Clean the filter regularly. If the filter is heavily stained and does not clean, or if it is damaged, replace the filter with a

new filter.

Otherwise, dirt may get inside and appear on the screen, preventing you from fully enjoying the video image. If dirt gets insid

e

or if you need information about the filter, consult authorized dealer where you purchased the projector or the nearest Service

 

Center.

 

1Turn off the MAIN POWER switch.

After the projector goes into stand-by state with the STAND BY indicator on, turn off the MAIN POWER switch and pull out the power cord from the projector and the wall outlet.

2Remove the filter.

Loosen the screw with a flat-end screwdriver.

Screw

Filter

Be careful not to damage the claws.

Notes

The screw is fitted so that it does not come off the filter.

If the filter is clogged with dirt, etc., the projector goes into an warning state (the OPERATE and STAND BY indicator blink. etc.). Therefore regularly, clean the filter. For the warning indication, refer to page 67.

3Clean the filter.

Clean the filter with a neutral detergent, wash it in water, and then dry it in the shade.

CAUTIONS

• Put on rubber gloves when using neutral detergent.

• After you have washed the filter in water, make sure the filter is completely dry before reinstalling it, otherwise an electri c shock or malfunction could occur.

• Do not clean the filter using a vacuum cleaner. Since the filter is soft, it may be sucked into the vacuum cleaner or damaged.

4Reinstall the filter.

Fasten the screw with a flat-end screwdriver.

Notes

 

 

• Install the filter correctly. Otherwise, the projector does not operate. (Goes into an warning state (For the warning indicati

on,

Refer to page 66).)

 

If the filter’s claws (in particular the claw which is hidden behind the filter cover knob) are damaged, the projector may not operate. Then, replace with a new filter.

63

ESPAÑOLITALIANO FRANÇAISDEUTSHENGLISH

Troubleshooting

Solutions to common problems related to your projector are described here. If none of the solutions presented here solves the problem, unplug the projector and consult an authorized dealer or Service Center.

 

Symptom

 

Probable cause

 

 

Corrective action

 

 

Page

Power

is not

 

Is the power cord disconnected?

Insert the power cord (plug) firmly.

 

 

30

supplied.

 

 

 

 

 

 

 

 

 

 

Is the MAIN POWER switch turned

 

 

• Turn on the MAIN POWER switch.

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on?

 

 

 

 

 

 

 

 

 

 

Is the fuse blown?

 

Turn off the MAIN POWER switch and

 

 

57

 

 

 

 

 

 

 

 

check the fuse.

 

 

 

 

 

 

 

 

 

 

 

If it is blown, replace it

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the lamp-replacement opening cover

 

• Turn off the MAIN POWER switch, close

 

 

7, 32, 60

 

 

 

 

 

closed correctly?

 

 

the lamp-replacement opening cover

 

 

 

 

 

 

 

 

 

 

 

correctly, and turn on the MAIN POWER

 

 

 

 

 

 

 

 

 

 

 

switch again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the filter closed correctly?

 

 

• Turn off the MAIN POWER switch, fit the

 

 

7, 32, 63

 

 

 

 

 

 

 

 

filter correctly, and turn on the MAIN

 

 

 

 

 

 

 

 

 

 

 

POWER switch again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has the lamp life expired? (Has the

 

 

• Turn off the MAIN POWER switch, replace

 

 

32, 58,

 

 

 

 

 

lamp use time reached 1000 hours in

 

 

with a new light-source lamp, and turn on

 

 

59, 62

 

 

 

 

 

the normal mode?)

 

 

the MAIN POWER switch.

 

 

 

 

 

 

 

 

(Has the lamp use time reached 2000

 

 

Reset the lamp use time after replacing with

 

 

 

 

 

 

 

hours in the LPC or LOC mode?)

 

 

a new lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Light is

not

emitted,

Is the lens cap removed?

 

Remove the lens cap.

 

30

 

or light

level is low.

 

 

 

 

 

 

 

 

Is the lamp life near its end?

 

Check the lamp use time on the menu, and

 

 

56, 58,

 

 

 

 

 

 

 

 

if the lamp life is near its end, arrange for a

 

59

 

 

 

 

 

 

 

 

replacement lamp, or replace a little earlier.

 

With

power

on,

Is the air intake or exhaust area

 

 

• Turn off the MAIN POWER switch, remove

 

 

6, 7, 32

operation starts but

 

blocked?

 

 

any blocking objects, and turn on the MAIN

 

 

 

stops in

a

few

 

 

 

 

POWER switch again.

 

 

 

minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video

image

does not

Is the correct input selected?

 

Select the correct input with the VIDEO and

 

 

9, 13

appear.

 

 

 

 

 

 

PC buttons.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are devices connected correctly?

Connect devices correctly.

11, 22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are signals being supplied from the

 

 

• Set connected devices correctly.

 

 

 

 

 

 

 

connected devices?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are input signals (scanning frequency,

 

 

• Check if the signal is appropriate (scanning

 

22, 23

 

 

 

 

 

etc.) appropriate?

 

 

frequency, etc.) and input the appropriate

 

 

 

 

 

 

 

 

 

signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the correct color system selected?

 

• Set the color system to AUTO or to the

 

 

45

 

 

 

 

 

 

 

 

correct dedicated color system.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is brightness adjusted correctly?

 

• Adjust brightness on the menu.

 

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is video turned off by pressing the

 

 

• Press the HIDE button to turn video on.

 

10,

12,

 

 

 

 

 

HIDE button?

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

During DVI input, are image signals

 

 

• If this happens, turn off the power to both

22

 

 

 

 

 

output from the computer graphic

 

 

the projector and the computer, and then

 

 

 

 

 

 

 

board (DVI output terminal)?

 

 

turn the projector back on before turning the

 

 

 

 

 

 

(During DVI input, depending on the

 

 

computer on again. Then correctly set the

 

 

 

 

 

 

 

 

computer settings, there may be no

 

 

computer’s graphic board.

 

 

 

 

 

 

 

 

signal input or an error may occur (blue

 

 

 

 

 

 

 

 

 

 

screen).)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video

image

dims.

Is focus adjusted correctly?

 

• Adjust focus.

 

 

12, 34

 

 

 

 

Is distance too short or too long?

 

 

• Set the projector at the correct distance.

 

18, 76,

 

 

 

 

 

 

 

 

 

 

 

77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are Tracking and Phase adjusted

 

 

• If satisfactory results are not obtained by

 

13, 36,

 

 

 

 

 

correctly?

 

 

pressing the QUICK ALIGN. button to

 

 

47

 

 

 

 

 

 

 

 

conduct quick alignment, adjust Tracking

 

 

 

 

 

 

 

 

 

 

 

and Phase on the menu.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video

image

is

Is picture quality (Brightness, etc.)

 

 

• Adjust picture quality on the menu.

 

 

49

abnormally dark or

adjusted correctly?

 

 

 

 

 

 

bright.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video

image

freezes.

Was the FREEZE button on the

 

 

• Press the FREEZE button to release

 

 

12, 37

 

 

 

 

 

remote control pressed?

 

 

freezing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64

DLA-G150CLU DLA-G150CLE

Page 73
Image 73
JVC No.51931 1-73, Cleaning and Replacing the Filter Cover, Troubleshooting, DLA-G150CLU DLA-G150CLE, Remove the filter