TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-98 August 9, 2005
Kaaaw sk
ERROR CODE E1106 Cannot execute in this robot.
This error occurs when a request is executed on a robot arm that does not support the
function.
Contact KRI customer service to have the function installed or delete the request.
_____________________________________________________________________
ERROR CODE E1108 Duplicate robot network IDs.
With the robot network installed and operational, the same ID number is assigned to two
different robots connected to the network.
Change the robot ID using the ROBNETID command.
_____________________________________________________________________
ERROR CODE E1109 Conveyor I/F board is not installed.
1JS board is not installed for interface with an incremental-type conveyor encoder.
1. 1JS board not installed to the 1GW/1HW board.
2. Defective 1JS board.
3. The 1JS board is installed onto a defective 1GW/1HW board.
Ensure the 1JS board is properly installed.
Replace the 1JS board.
Replace the 1JS board and the 1GW/1HW board.
_____________________________________________________________________
ERROR CODE E1110 GROUP is not primed.
The GROUP instruction is not programmed before a motion instruction, with external
axis system.
This error occurs if the program is interrupted after a GROUP instruction and before
the motion commands pertaining to the GROUP instruction are complete. When
restarting the program prime the program before the GROUP instruction.
In check mode, if the GROUP instruction is used, start checking before the GROUP
instruction.
_____________________________________________________________________