TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-178 August 9, 2005
Kaaaw sk
ERROR CODE P1029 Program name not specified.
Displayed when no program is on the stack and the EDIT command is entered without
specifying a program name.
Specify the name of the program to edited.
_____________________________________________________________________
ERROR CODE P1030 Program interlocked by other procedure.
The selected program is not recognized as a robot program or a PC program and is
used by another part of the software.
Initialize the system and reload the program.
_____________________________________________________________________
ERROR CODE P1031 No free memory.
Main causes include:
1. Not enough free memory to edit or teach a program.
2. Too many paths registered for arc welding (900 paths allowed in database).
Delete unused programs and variables, or, expand system memory to maintain the
required capacity.
Store 900 or less arc welding paths in database.
_____________________________________________________________________
ERROR CODE P1032 No program step.
The step specified for execution or copying does not exist in program.
Select valid steps for execution.
Create step(s) in the program.
_____________________________________________________________________
ERROR CODE P1033 Program name already exists.
When using the RENAME or COPY command a new program name must be specified.
If an existing name is used this error is displayed.
Specify unused program names when renaming or copying programs.
If not needed, delete the existing program with the name used.
_____________________________________________________________________