TROUBLESHOOTING
1-19August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
ERROR CODE D1002 Init. error of servo software.
Servo software
(armsc.mb)
initialization failure at controller power-up.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Incompatibility between the AS and servo software.
3. Defective 1KA and or 1KB board.
Reinstall servo software.
Check compatibility of AS and servo software and reinstall software as needed.
Replace the 1KA and or 1KB boards.
_____________________________________________________________________
ERROR CODE D1003 Init. error of servo control software.
Servo software
(armsv.abs)
initialization failure at controller power-up.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Incompatibility between the AS and servo software.
3. Defective 1KA and or 1KB board.
Reinstall servo software.
Check compatibility of AS and servo software and reinstall software as needed.
Replace the 1KA and or 1KB boards.
_____________________________________________________________________