TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-198 August 9, 2005
Kaaaw sk
ERROR CODE P6500 Cannot generate working line direction.
This error occurs when weld start and end points are the same, and motion direction
cannot be determined.
Ensure the start and end points are not the same.
_____________________________________________________________________
ERROR CODE P6501 Illegal tool posture.
The tool angle (angle between torch and welding line; also called torch angle) is 0 de-
grees and the welding cannot be executed.
Teach a third point besides the weld start and end points above the line between the
start and end points so that the torch assumes an appropriate angle.
_____________________________________________________________________
ERROR CODE P6502 No weld database.
The arc weld condition database specified by the source program does not exist.
Create arc weld condition database specified by the program
.
_____________________________________________________________________
ERROR CODE P6503 Cannot change weld condition.
An attempt is made to change weld conditions using the real time weld condition modifi-
cation function without selecting check mode and WELD ON.
To change weld conditions using the real time weld condition modification function.
1. Select check mode.
2. Set WELD ON.
3. Change weld conditions.
_____________________________________________________________________
ERROR CODE P6504 Step:XX Preceding L.START missing.
This error occurs when an L.START instruction does not proceed an L.END instruction.
Add a step containing an L.START instruction before the step containing the L.END
instruction.