TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-52 August 9, 2005
Kaaaw sk
ERROR CODE D2016 No response from the arm control board.
Request is sent to the 1KB board from the 1KA board and there is no response.
Reset error and if error recurs, replace the 1KA/1KB boards
.
_____________________________________________________________________
ERROR CODE D2017 No response from User I/F board.
1KA board software stopped.
Main causes include:
1. AS software is not installed correctly or is corrupt.
2. Defective 1KA board.
Reinstall correct AS software.
Replace 1KA board
.
_____________________________________________________________________
ERROR CODE D2018 [ARM CTRL BOARD] no response.
1KB board software stopped.
Main causes include:
1. AS software is not installed correctly or is corrupt.
2. Defective 1KB board.
Reinstall correct AS software.
Replace 1KB board
.
_____________________________________________________________________
ERROR CODE D2019 [ARM CTRL BOARD] servo software no response.
1KB board software stopped.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Defective 1KB board.
Reinstall correct 1KB board servo software to the 1KA board.
Replace 1KB board
.
_____________________________________________________________________