TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-90 August 9, 2005
Kaaaw sk
ERROR CODE E1067 Illegal pattern type.
Main causes include:
1. Program step does not comply with AS Language syntax.
2. Pattern type for work specified using block step instructions or the PALLET function is
not between 1 and 5.
Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
Ensure the work pattern number specified is correct.
_____________________________________________________________________
ERROR CODE E1068 Illegal work data.
Main causes include:
1. Program step does not comply with AS Language syntax.
2. Work data specified using block step instructions or the PALLET function is incorrect
or not registered.
Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
Ensure the work data specified is correct.
_____________________________________________________________________
ERROR CODE E1069 Illegal pallet data.
Main caused include:
1. Program step does not comply with AS Language syntax.
2. Pallet data in a block step program, the PALUP instruction or the PALLET function, is
incorrect or not registered.
Refer to the D Series Controller AS Language Reference Manual for proper use of
the AS Language commands.
Ensure the pallet data specified is correct.
_____________________________________________________________________
ERROR CODE E1070 ON/ONI signal is already input.
An ON/ONI instruction mode “/ERR” is specified and the signal condition to monitor is
already attained when monitoring starts.
Delete the “/ERR” mode from the ON/ONI instruction or specify “/LVL” mode
.
Modify the program so the signal condition is not attained until monitoring starts.
_____________________________________________________________________