TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-50 August 9, 2005
Kaaaw sk
ERROR CODE D2006 Communication board to explosion-proof teach pendant
watch-dog error.
This error occurs when the CPU on the communication board (1GS board) for the explo-
sion-proof teach pendant is suspended.
Main causes include:
1. Defective communication board (1GS board).
2. Defective main CPU board (1KA board).
Replace defective 1GS board.
Replace defective 1KA board.
_____________________________________________________________________
ERROR CODE D2007 No response from the built-in sequence board.
This error occurs when the built-in PLC is in an error condition or the program mode.
Cycle the controller power OFF and ON after the cause of the built-in PLC error is
corrected.
Set the built-in PLC to the operating mode.
_____________________________________________________________________
ERROR CODE D2008 Arm ID I/F board error. (code XX).
This error occurs when a communication error exists between the arm ID board inter-
face board (1KP) and the arm ID board (1GV) (abnormal ROM, RAM, DPRAM, etc.).
Replace the arm ID board (1GV).
Replace the arm ID interface board (1KP).
Check and repair or replace harnesses and connections as necessary.
_____________________________________________________________________
ERROR CODE D2010 Sync. error between user I/F and arm control board.
1KA and 1KB board synchronization failed for 1 second or more.
Replace 1KA board
.
Replace 1KB board
.
_____________________________________________________________________