TROUBLESHOOTING
1-57August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
ERROR CODE D2035 Program execution error.
Program failed to start when cycle start command was issued.
Reset the error, and restart the program
.
If the error recurs, contact KRI Customer Service
.
_____________________________________________________________________
ERROR CODE D2036 (SSCNET) system error occurred in 1LP I/F board. (code
XX)
Main causes include:
1. Defective 1LP board (1KB daughter board)
2. 5 VDC power supply voltage dropped to 4.5 VDC or less.
Replace 1LP board.
Adjust 5 VDC power supply to specifications then cycle controller power OFF and
ON.
_____________________________________________________________________
ERROR CODE D4500 Fieldbus interface board is not detected.
The I/F board specified in AUX 0608-2 is not installed.
Set controller power OFF and install the specified I/F board.
If specified I/F board is installed, verify proper installation.
Ensure settings in AUX 0608-2 are correct.
Ensure I/F board LED indicator displays proper operation.
Ensure 1JF board jumper settings are correct.
_____________________________________________________________________
ERROR CODE D4501 ABMA-PDP) I/F module error. XX
Improperly installed or defective ABMA-PDP module
Check error code
.
Ensure 1JF board and I/F board are properly installed and cycle controller power
OFF and ON.
If error recurs, check LED1 on the I/F card.
If the LED is ON, execute configuration.
If the LED is OFF, contact I/F card manufacturer.
_____________________________________________________________________