TROUBLESHOOTING
1-195August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
ERROR CODE P2074 Floppy disk is broken.
This error occurs when ten or more defective sectors are detected on a floppy disk.
Use a new or known good floppy disk.
_____________________________________________________________________
ERROR CODE P2075 Channel number of JtXX is incorrect.
Main causes include:
1. Non-existing channel number is allocated.
2. Board for driving Mitsubishi motor is not installed or incorrect board is installed on the
1KB board.
Ensure the external axis channel number set in AUX 2002 is correct
.
Ensure the correct Mitsubishi motor driving board is installed to the 1KB board.
_____________________________________________________________________
ERROR CODE P4500 FIELD-BUS) Interface not enabled.
Main causes include:
1. An attempt is made to execute the PROFIBUS (/DEVNET) command without register-
ing the appropriate fieldbus interface.
2. The PROFIBUS (/DEVNET) interface card is not installed.
Ensure the fieldbus interface is registered.
Ensure the fieldbus interface card is properly installed.
_____________________________________________________________________
ERROR CODE P4501 DEVNET) Node XX not in the scanlist.
An attempt is made to execute the DEVNET command to a slave that is not in the
scanlist.
Ensure the MAC_ID, settings and parameters for the device to receive the monitor
command are correct and re-execute the DEVNET command
.
_____________________________________________________________________