TROUBLESHOOTING
1-77August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Kaaaw sk
ERROR CODE E1034 Encoder initialize error (Jt XX).
The encoder is not able to read the absolute position at control power on. The scanning
of absolute data begins immediately after a shift from the state of non-operation, or
back-up operation, to normal encoder operation. BUSY=1 is output until the absolute
position has been determined.
Power
circuit Battery
EncoderEncoder
1FG/1HG board
Robot
Controller
1KB board
Encoder I/F
Servo
CPU
Encoder +12VDC power supply
Main causes include:
1. Encoder rotated at 300 RPM or more at controller power-up (including conveyor
encoder).
2. Defective encoder or encoder harness.
3. Defective 1KB, 1KQ/1NR, or 1GF/1HG board.
4. Defective manual brake release.
In the case of a conveyor encoder, ensure power-up speed is below 300 RPM.
Check connections at encoder, 1FG/1HG board.
Ensure the 1KB board is properly seated into the card rack.
Replace encoder, replace 1KB, 1KQ/1NR, or 1FG/1HG board.
Check for continuity in the machine harness, separation and signal harness repair or
replace as necessary.
For additional information on error code E1034, see section 1.4.