TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-190 August 9, 2005
Kaaaw sk
ERROR CODE P2051 Illegal sequence numbers for file I/O data.
During data transfer between the 1KA and 1KF boards, the response from the 1KF
board does not conform to the request from the 1KA board.
Replace the 1KA/1KF boards
.
Replace the harness between the 1KA and 1KF boards.
Check for noise malfunction and shield integrity.
_____________________________________________________________________
ERROR CODE P2052 [LSEQ] Program includes unavailable instructions.
An unavailable instruction is included in basic operation part of the KLogic program
(lsqpg).
Example: JMOVE.
Delete unavailable instruction form the KLogic program
(lsqpg).
_____________________________________________________________________
ERROR CODE P2053 [LSEQ] Too many steps exist.
An excessive number of steps exist in the basic operation part of the KLogic program
(lsqpg).
Correct the KLogic program so the number of steps does not exceed the maximumnumber of steps allowed (10,000 steps maximum).
_____________________________________________________________________
ERROR CODE P2054 [LSEQ] Invalid type of signal variable.
An instruction that specifies an invalid signal variable as an argument is used in the
basic operation part of the KLogic program.
Example: LSQ OUT,&X0000.
Ensure a valid signal variable is used in the KLogic program
.
Example: LSQ OUT,&Y0000.
_____________________________________________________________________